Safety Data Sheet
SR-17018 · CAS 2134602-45-0 · Version 1.2 · Issued 2026-01-20
GHS-format SDS, Sections 1–16. Prepared in accordance with OSHA HCS 2012 and EU Regulation (EC) No 1907/2006 (REACH).
Identification
Product name: SR-17018. CAS 2134602-45-0. Supplier: SR Biosciences. Intended use: In vitro research reagent. Emergency contact on file.
Hazard Identification
Not classified as hazardous under GHS criteria based on available data. Research use only. Handle with appropriate precautions as for any novel research compound.
Composition / Information on Ingredients
Single-component substance. Chemical name: SR-17018. CAS Number: 2134602-45-0. Molecular formula: C₂₁H₁₆Cl₄N₄. MW: 490.22 g/mol.
First-Aid Measures
Skin contact: wash with soap and water. Eye contact: flush with copious water for 15 minutes; seek medical attention. Inhalation: remove to fresh air. Ingestion: do not induce vomiting; contact a physician immediately.
Fire-Fighting Measures
Suitable extinguishing media: CO₂, dry powder, foam. Do not use water jet. Wear self-contained breathing apparatus and full protective equipment in case of fire.
Accidental Release Measures
Sweep up solid material; avoid generating dust. Place in sealed, labelled waste container. Dispose of according to local regulations. Prevent entry into drains or waterways.
Handling and Storage
Store at −20 °C under inert atmosphere with desiccant. Keep container tightly sealed when not in use. Protect from light, moisture, and heat. Use in a well-ventilated area. Observe standard laboratory safety precautions.
Exposure Controls / Personal Protection
Engineering controls: use in a chemical fume hood or ventilated enclosure. PPE: laboratory coat, chemical-resistant gloves (nitrile), and safety glasses minimum. Respiratory protection if handling as powder.
Physical and Chemical Properties
Appearance: white to off-white crystalline powder. Odour: odourless. Solubility: DMSO ≥10 mM; ethanol slightly soluble; water insoluble. Melting point: not determined. Stability: ≥24 months at −20 °C.
Stability and Reactivity
Stable under recommended storage conditions. Avoid exposure to moisture, strong oxidising agents, strong acids, and strong bases. Hazardous decomposition products: hydrogen chloride, nitrogen oxides.
Toxicological Information
Acute toxicity data not fully established. SR-17018 is a potent μ-opioid receptor agonist; treat with extreme caution. No exposure limits established. Research use only — not for human or veterinary use.
Ecological Information
Ecotoxicity data not available. Avoid release to the environment. Do not allow to enter drains, sewers, or waterways.
Disposal Considerations
Dispose of contents and container in accordance with local, regional, and national regulations. Do not dispose of as general waste. Recommended method: incineration at a licensed facility.
Transport Information
Not classified as dangerous goods under ADR, IATA, or IMDG regulations based on available data. Ship ambient with desiccant as standard. Consult carrier for current requirements.
Regulatory Information
SR-17018 is not currently a scheduled controlled substance in the United States or EU. Researchers are responsible for compliance with all applicable local, national, and international regulations governing possession and use.
Other Information
This SDS was prepared based on information available at the time of preparation. SR Biosciences provides this document as a courtesy; it does not constitute a warranty of safety. For research use only.